Last data update: May 06, 2024. (Total: 46732 publications since 2009)
Records 1-9 (of 9 Records) |
Query Trace: Ding YS[original query] |
---|
Multi-year Study of PAHs in Mainstream Cigarette Smoke
Hearn BA , Ding YS , Watson CH , Johnson TL , Zewdie G , Jeong-Im JH , Walters MJ , Holman MR , Rochester CG . Tob Regul Sci 2018 4 (3) 96-106 OBJECTIVES: Correlations are made between mainstream cigarette smoke deliveries of individual PAHs over multiple years. Average overall PAH deliveries in mainstream cigarette smoke by study year, mentholation, ring size, and manufacturer are compared. METHODS: Mainstream smoke deliveries were determined by GC/MS for 14 polycyclic aromatic hydrocarbons (PAHs) from selected cigarettes on the US market in 2002, 2004, 2007, and 2011. The mainstream smoke PAH emissions were measured under international standardization organization (ISO) smoking conditions. Pearson product-moment correlation was used to examine the linear relationship among the PAHs over multiple years. RESULTS: A number of the PAH analytes were statistically highly correlated with each other. The overall average for mainstream smoke deliveries of PAHs did not change significantly between study years. Similar levels in average PAH deliveries were seen for mentholated and non-mentholated cigarettes. CONCLUSIONS: The strong correlations between PAH compounds over multiple years show that a limited set of PAHs can predict deliveries of others with confidence over multiple years. A more limited panel of analytes may be considered when designing studies involving PAH measurements in mainstream smoke. |
The use of charcoal in modified cigarette filters for mainstream smoke carbonyl reduction
Morabito JA , Holman MR , Ding YS , Yan X , Chan M , Chafin D , Perez J , Mendez MI , Cardenas RB , Watson C . Regul Toxicol Pharmacol 2017 86 117-127 Carbonyls are harmful and potentially harmful constituents (HPHCs) in mainstream cigarette smoke (MSS). Carbonyls, including formaldehyde and acrolein, are carcinogenic or mutagenic in a dose-dependent manner. Past studies demonstrate significant reduction of HPHCs by charcoal filtration. However, limits of charcoal filtration and cigarette design have not yet been investigated in a systematic manner. Objective data is needed concerning the feasibility of HPHC reduction in combustible filtered cigarettes. This systematic study evaluates the effect of charcoal filtration on carbonyl reduction in MSS. We modified filters of ten popular cigarette products with predetermined quantities (100-400 mg) of charcoal in a plug-space-plug configuration. MSS carbonyls, as well as total particulate matter, tar, nicotine, carbon monoxide (TNCO), and draw resistance were quantified. Significant carbonyl reductions were observed across all cigarette products as charcoal loading increased. At the highest charcoal loadings, carbonyls were reduced by nearly 99%. Tar and nicotine decreased modestly (<20%) compared to reductions in carbonyls. Increased draw resistance was significant at only the highest charcoal loadings. This work addresses information gaps in the science base that can inform the evaluation of charcoal filtration as an available technological adaptation to cigarette design which reduces levels of carbonyls in MSS. |
Chemical characterization of mainstream smoke from SPECTRUM VARIABLE NICOTINE RESEARCH CIGARETTES
Ding YS , Richter P , Hearn B , Zhang L , Bravo R , Yan X , Perez JJ , Chan M , Hughes J , Chen P , Chen W , Wong J , Holmberg S , Smith S , Larango M , Valentin-Blasini L , Watson CH . Tob Regul Sci 2017 3 (1) 81-94 OBJECTIVE: Our objective was to characterize mainstream smoke constituent deliveries from SPECTRUM variable nicotine research cigarettes under 2 machine smoking regimens. SPECTRUM cigarettes are manufactured by the 22nd Century company for the National Institute on Drug Abuse, National Institutes of Health to contain varying (including reduced) levels of nicotine. METHODS: Mainstream smoke constituent deliveries of "tar," nicotine, carbon monoxide, tobacco-specific nitrosamines (N'-nitrosonornicotine (NNN) and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK)), benzo[a]pyrene, aromatic amines, and carbonyls were analyzed in 23 varieties of SPECTRUM cigarettes using ISO 17025 accredited methods. RESULTS: Data are presented as means and standard deviations of 5 replicates for all analytes. CONCLUSIONS: Under the ISO smoking regimen, mean levels of many smoke emissions for SPECTRUM varieties were comparable to the 3R4F research cigarette. Calculated SPECTRUM elasticity ranged from 1.6 to 4.0. Accordingly, under intense machine smoking conditions differences in emissions of SPECTRUM cigarettes were apparent. In addition, NNN increased with smoke nicotine while the same rate of change was not seen for NNK. It is important to monitor levels of chemicals of public health concern and regulatory interest as technologies emerge to reduce levels of nicotine or other targeted chemicals in tobacco products. |
Tobacco-specific nitrosamines in the tobacco and mainstream smoke of U.S. Commercial cigarettes
Edwards SH , Rossiter LM , Taylor KM , Holman MR , Zhang L , Ding YS , Watson CH . Chem Res Toxicol 2016 30 (2) 540-551 Tobacco-specific nitrosamines (TSNAs) are N-nitroso-derivatives of pyridine-alkaloids (e.g., nicotine) present in tobacco and cigarette smoke. Two TSNAs, N'-nitrosonornicotine (NNN) and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), are included on the Food and Drug Administration's list of harmful and potentially harmful constituents (HPHCs) in tobacco products and tobacco. The amounts of four TSNAs (NNK, NNN, N-nitrosoanabasine (NAB), and N'-nitrosoanatabine (NAT)) in the tobacco and mainstream smoke from 50 U.S. commercial cigarette brands were measured from November 15, 2011 to January 4, 2012 using a validated HPLC/MS/MS method. Smoke samples were generated using the International Organization of Standardization (ISO) and Canadian Intense (CI) machine-smoking regimens. NNN and NAT were the most abundant TSNAs in tobacco filler and smoke across all cigarette brands, whereas NNK and NAB were present in lesser amounts. The average ratios for each TSNA in mainstream smoke to filler content is 29% by the CI smoking regimen and 13% for the ISO machine-smoking regimen. The reliability of individual TSNAs to predict total TSNA amounts in the filler and smoke was examined. NNN, NAT, and NAB have a moderate to high correlation (R2 = 0.61-0.98, p < 0.0001), and all three TSNAs individually predict total TSNAs with minimal difference between measured and predicted total TSNA amounts (error < 7.4%). NNK has weaker correlation (R2 = 0.56-0.82; p < 0.0001) and is a less reliable predictor of total TSNA quantities. Tobacco weight and levels of TSNAs in filler influence TSNA levels in smoke from the CI machine-smoking regimen. In contrast, filter ventilation is a major determinant of levels of TSNAs in smoke by the ISO machine-smoking regimen. Comparative analysis demonstrates substantial variability in TSNA amounts in tobacco filler and mainstream smoke yields under ISO and CI machine-smoking regimens among U.S. commercial cigarette brands. |
In situ derivatization and quantification of seven carbonyls in cigarette mainstream smoke
Ding YS , Yan X , Wong J , Chan M , Watson CH . Chem Res Toxicol 2016 29 (1) 125-31 Carbonyls, especially aldehydes, are a group of harmful volatile organic compounds that are found in tobacco smoke. Seven carbonyls are listed on the FDA's harmful and potential harmful constituents list for tobacco or tobacco smoke. Carbonyls have reactive functional groups and thus are challenging to quantitatively measure in cigarette smoke. The traditional method of measuring carbonyls in smoke involves solvent-filled impinger trapping and derivatization. This procedure is labor-intensive and generates significant volumes of hazardous waste. We have developed a new method to efficiently derivatize and trap carbonyls from mainstream smoke in situ on Cambridge filter pads. The derivatized carbonyls are extracted from the pads and subsequently quantified by ultra-high-pressure liquid chromatography coupled with tandem mass spectrometry. The new method has been validated and applied to research and commercial cigarettes. Carbonyl yields from research cigarettes are comparable to those from other published literature data. With a convenient smoke collection apparatus, a 4 min sample analysis time, and a low- or submicrogram detection limit, this new method not only simplifies and speeds the detection of an important class of chemical constituents in mainstream smoke but also reduces reactive losses and provides a more accurate assessment of carbonyl levels in smoke. Excellent accuracy (average 98%) and precision (14% average relative standard deviation in research cigarettes) ensure this new method's sufficient fidelity to characterize conventional combusted tobacco products, with potential application toward new or emerging products. |
Polycyclic aromatic hydrocarbons in the mainstream smoke of popular U.S. cigarettes
Vu AT , Taylor KM , Holman MR , Ding YS , Hearn B , Watson CH . Chem Res Toxicol 2015 28 (8) 1616-26 The mainstream smoke yields of 14 polycyclic aromatic hydrocarbons (PAHs) were determined for 50 commercial U.S. cigarettes using a validated GC/MS method with the International Organization of Standardization (ISO) and Canadian Intense (CI) smoking machine regimens. PAH mainstream smoke deliveries vary widely among the commercial cigarettes with the ISO smoking regimen primarily because of differing filter ventilation. The more abundant, lower molecular weight PAHs such as naphthalene, fluorene, and phenanthrene predominantly comprise the total PAH yields. In contrast, delivery yields of high molecular weight PAHs such as benzo[b]fluoranthene, benzo[e]pyrene, benzo[k]fluoranthene, and benzo[a]pyrene (BaP) are much lower. Comparative analysis of PAHs deliveries shows brand specific differences. Correlation analysis shows strong positive associations between BaP and most of the other PAHs as well as total PAHs. The results suggest that BaP may be a representative marker for other PAH constituents in cigarette smoke generated from similarly blended tobacco, particularly those PAHs with similar molecular weights and chemical structures. |
Mouth-level intake of benzo[a]pyrene from reduced nicotine cigarettes
Ding YS , Ward J , Hammond D , Watson CH . Int J Environ Res Public Health 2014 11 (11) 11898-11914 Cigarette smoke is a known source of exposure to carcinogenic polycyclic aromatic hydrocarbons (PAHs), especially benzo[a]pyrene (BaP). Exposure to BaP in cigarette smoke is influenced by how a person smokes and factors, such as tobacco blend. To determine whether sustained use of reduced-nicotine cigarettes is associated with changes in exposure to nicotine and BaP, levels of BaP in spent cigarette filter butts were correlated with levels of BaP in cigarette smoke to estimate mouth-level intake (MLI) of BaP for 72 daily smokers given three progressively reduced nicotine content cigarettes. Urinary cotinine, a marker of nicotine exposure, and urinary 1-hydroxypyrene (1-HOP), a marker of PAH exposure, were measured throughout the study. Median daily BaP MLI and urine cotinine decreased in a similar manner as smokers switched to progressively lower nicotine cigarettes, despite relatively constant daily cigarette consumption. 1-HOP levels were less responsive to the use of reduced nicotine content cigarettes. We demonstrate that spent cigarette filter butt analysis is a promising tool to estimate MLI of harmful chemicals on a per cigarette or per-day basis, which partially addresses the concerns of the temporal influence of smoking behavior or differences in cigarette design on exposure. |
Chemical analysis of Alaskan iq'mik smokeless tobacco
Hearn BA , Renner CC , Ding YS , Vaughan-Watson C , Stanfill SB , Zhang L , Polzin GM , Ashley DL , Watson CH . Nicotine Tob Res 2013 15 (7) 1283-8 INTRODUCTION: Iq'mik, a form of smokeless tobacco (ST), is traditionally used by Cup'ik and Yup'ik Eskimo people of western Alaska. Iq'mik is sometimes incorrectly considered to be a healthier alternative to smoking because its ingredients are perceived as "natural." Our chemical characterization of iq'mik shows that iq'mik is not a safe alternative to smoking or other ST use. METHODS: We measured nicotine and pH levels of tobacco and ash used to prepare iq'mik. We also characterized levels of toxins which are known to be present in ST including tobacco-specific nitrosamines (TSNAs) and polycyclic aromatic hydrocarbons (PAHs) using chromatographic separations coupled with isotope dilution mass spectrometry. RESULTS: Nicotine content in the iq'mik tobacco was very high, ranging from 35 to 43mg/g, with a mean of 39mg/g. The pH of the iq'mik tobacco-ash mixture was 11, an extremely high level compared with most ST products. High levels of PAHs were seen in the fire-cured tobacco samples with a benzo[a]pyrene level of 87ng/g. Average TSNA levels in the tobacco were 34, 2,700, and 340ng/g for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), N'-nitrosonornicotine (NNN), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), respectively. CONCLUSIONS: Iq'mik contains high levels of the more easily absorbed unionized nicotine as well as known carcinogenic TSNAs and PAHs. The perception that iq'mik is less hazardous than other tobacco products due to the use of "natural" ingredients is not warranted. This chemical characterization of iq'mik gives a better understanding of the risk of possible adverse health effects of its use. |
Semi-volatiles in mainstream smoke delivery from select charcoal-filtered cigarette brand variants
Hearn BA , Ding YS , Vaughan C , Zhang L , Polzin G , Caudill SP , Watson CH , Ashley DL . Tob Control 2010 19 (3) 223-30 BACKGROUND: It has been reported that charcoal added to cigarette filters selectively removes many of the more volatile chemicals, but it is not clear to what extent charcoal may reduce the delivery of important less volatile chemical constituents in mainstream cigarette smoke. METHODS: We analysed machine-derived mainstream smoke deliveries (under three smoking regimens) for variants of a charcoal-filtered cigarette commercially test-marketed in the USA, focusing on selected polycyclic aromatic hydrocarbons (PAHs), phenols and tobacco-specific nitrosamines (TSNAs). Results While charcoal-containing filters selectively removed lower molecular weight PAHs from mainstream smoke, they did not significantly remove the heavier and more toxic PAHs studied, such as benzo[a]pyrene, a known carcinogen. Likewise, charcoal-containing filters removed phenols and TSNAs from mainstream smoke to differing amounts depending on the compound, filter design and the smoking regimen. CONCLUSIONS: The addition of sufficient charcoal to cigarette filters is known to remove many volatile compounds and can potentially reduce deliveries of certain semi-volatile compounds under some machine smoking regimens. Less volatile compounds, with a significant portion in the particulate phase, are less available for selective filtration by charcoal-containing filters than the more volatile compounds that reside predominantly in the gas phase. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure